NexiGo Projector
Repair Centre
We are the UK's premier repair centre for **NexiGo**. From the flagship **Aurora Pro 4K UST** to the popular **PJ40 LCD** series, we resolve optical burn-in, laser alignment, and smart system faults.
Technician's Note:
"The **NexiGo PJ40** and similar Single-LCD models rely heavily on airflow to cool the LCD panel. If dust filters are neglected, the panel overheats, creating a permanent brown or yellow burn spot in the centre of the image. We replace these panels and upgrade the cooling pathway."
— LCD & Laser Engineer
Mastering Laser & LCD Tech
NexiGo offers two distinct technologies: **Single-LCD** for their portable/budget range and **Triple Laser (Tri-Color)** for the premium Aurora UST. Each requires specific expertise to repair correctly.
The "Brown Spot" Issue (PJ Series): LCD projectors work by passing powerful light through a liquid crystal display. If cooling fails, the polariser film literally burns. This manifests as a brownish-yellow discoloration in the centre of the screen. We strip the optical engine, clean the fresnel lenses, and install a new high-temp resistant LCD panel.
Aurora Pro Calibration: The Aurora Pro uses RGB lasers to achieve Dolby Vision standards. If the image appears misaligned or has colour fringing (red/green ghosts), the internal UST mirror array or laser banks need recalibration on an optical bench.
LCD Replacement
Replacing burnt panels to fix brown/yellow spots on PJ20/PJ40.
Tri-Color Laser
Calibration of the RGB light engine for Aurora Pro colour accuracy.
Auto-Focus
Repairing focus motors and ToF sensors on smart portable units.
Optical Clean
Deep cleaning of internal mirrors and lenses to remove dust spots.
NexiGo Error Code Database
NexiGo projectors communicate faults via on-screen messages or LED indicators. Use this matrix to identify your issue.
| Indicator / Message | Likely Fault | Engineer's Note |
|---|---|---|
| Brown/Yellow Spot in Center | LCD Panel Burn | Critical. The polarising layer on the LCD has burnt due to heat. The panel is permanently damaged and requires replacement. |
| "Fan Error" / Shutdown | Cooling Failure | The RPM sensor on the intake or exhaust fan is reading zero. The system shuts down to prevent fire risk. We replace the fan unit. |
| No Signal (HDMI) | Mainboard / Port Damage | The HDMI port solder joints may be fractured, or the input processing chip has failed. Requires microsoldering repair. |
| Black Spots (Dust) | Optical Contamination | Distinct black specks that come into focus when you adjust the lens. Dust has entered the 'sealed' optical engine. Requires strip-down and cleaning. |
| Aurora Pro: No 3D Sync | DLP Link Failure | The projector fails to send the white-flash sync signal. Often a firmware glitch or a fault on the DMD driver board. |
Supported NexiGo Families
Aurora Series
Triple Laser UST
We service the flagship Aurora Pro. Expert calibration of the Tri-Color laser engine and Dolby Vision handshake repair.
- • Aurora Pro (4K UST)
- • Aurora (Standard)
PJ Series
LCD / Portable
Diagnostics for the popular PJ LCD range. We fix brown burn spots, loud fans, and power input failures.
- • PJ40 (Gen 3)
- • PJ20 / PJ10
- • PJ90 (Outdoor)
Restore Your NexiGo Experience
Don't let a brown spot or fan noise ruin your movie night. Our engineers are ready to restore your NexiGo unit to factory spec.
Authorised Quality Service | 90-Day Warranty on All Repairs | Nationwide Collection